Atlantic1952:
Nicely spider infested and yes, that's Asbestos over the mains dropper!
Atlantic1952:
SANY3316
Atlantic1952:
SANY3317
Atlantic1952:
The mains dropper is set for 200-225V operation
Atlantic1952:
S/N 10681
Atlantic1952:
The rear showing the asbestos heat shield
Atlantic1952:
Thankfully this set still has its correct control knobs
Atlantic1952:
The set needs to be stripped, cleaned and repaired
Atlantic1952:
The set needs to be stripped, cleaned and repaired
Atlantic1952:
The set needs to be stripped, cleaned and repaired
Atlantic1952:
The first IFT coil can
Atlantic1952:
The first IFT coil can
Atlantic1952:
SANY0028
Atlantic1952:
SANY0029
Atlantic1952:
SANY0030
Atlantic1952:
SANY0031
Atlantic1952:
SANY0032
Atlantic1952:
Removing the first IFT coil can
Atlantic1952:
Unwrapping the first IFT coils
Atlantic1952:
IFT 1 secondary should have been 9 or 10 Ohms!
Atlantic1952:
Measuring the IFT1 secondary coil
Atlantic1952:
SANY0038
Atlantic1952:
The first IFT coils on their former.
Atlantic1952:
SANY0044
Atlantic1952:
SANY0045
Atlantic1952:
The coil on the left was open circuit!
Atlantic1952:
SANY0047
Atlantic1952:
The corroded IFT secondary had to be repaired
Atlantic1952:
The repaired 2nd IFT secondard coil
Atlantic1952:
Installing the rewound first IFT